Microwave sensor |
|
MBF |
Microwave type level sensor |
|
|
Stable operation under severe environment because of using microwave |
This device is a through-beam type microwave sensor. This is suitable for waste level detection in hopper at waste processing facility.
|
Model No. |
MBF-26T(Transmitter) |
MBF-23T(Transmitter) |
|
Applied microwave |
24.15GHz |
|
|
Oscillating output |
10mW |
|
|
Setting distance |
5m or less(Max. 50m) |
|
|
Antenna directive angle |
17° |
|
|
Control output(Receiver) |
1C relay, excited when microwave is received(250VAC 4A cosφ=1, 30VDC 3A) |
|
|
Timer |
ON delay, adjustable during 0.1 to 10sec |
|
|
Power source |
24VDC(18 to 30VDC both projector and receiver) |
100 to 230VAC(85 to 250VAC) 50/60Hz(both projector and receiver) |
|
Power consumption |
3W or less : transmitter |
3.2VA or less : transmitter |
|
Ambient temperature |
-10 to +50 degrees C |
|
|
Ambient humidity |
45 to 85%RH |
|
|
Vibration resistance |
Double amplitude 1.5mm 10 to 55Hz each 2 hour in X, Y and Z direction |
|
|
Impact resistance |
196m/s2 , Each 3 time in X, Y and Z directions |
|
|
Insulation resistance |
20MΩ or more(by 250VDC megger) |
20MΩ or more(by 500VDC megger) |
|
Protective structure |
IP64(IEC standard) |
|
|
Installation |
Flange installation(in conformity with JIS B2210, nominal diameter 65) |
|
|
Case material |
Body : aluminum die-casting, cover : acrylic resin |
|
|
Weight |
Each approx. 2.5kg |
|
|
Transmitter |
Receiver |
||||||||||||||||
|
|
|
||||||||||||||||
|
*Value in parenthesis is MBF-26T/R |
|
||||||||||||||||
|
Control output |
|
||||||||||||||||
|
|||||||||||||||||