Common Features |
|
![]() |
Compact design with integrated ignition transformer and flame monitor/burner control |
![]() |
Built-in flame ionization electrode, ideally located |
![]() |
No high-voltage cable required on site |
![]() |
Guaranteed electromagnetic compatibility |
![]() |
Rugged, low-maintenance design |
![]() |
Sizes ranging from 2 kW to 10 MW (7,000 BTU/hr to 35,000,000 BTU/hr) |
![]() |
Custom tube lengths available in 10-mm increments |
![]() |
Fuel types include natural gas, conditioned coke oven gas, propane/butane or process gas, according to customer preference and analysis |
![]() |
Extremely tight and long pilot flame - no automatic retraction system typically required |
![]() |
Class 1, 2 or 3 igniters according to NFPA also available |
![]() |
Also available with flexible igniter tube for tilting burners |
Product overview: gas igniters
Hegwein Heat release max. |
|
2 kW | |
![]() |
Ignition of gas burners up to 500 kW |
![]() |
Application in heat treatment plants and where space is limited |
Common Data | |
tube Ø |
15 mm |
flame length |
max. 80 mm |
igniter tube length L |
120 – 2400 mm |
gas inlet |
1/4“ |
gas pressure |
15 – 20 mbarg |
air inlet |
1/4“ |
air pressure |
15 – 20 mbarg |
Transformer part (not ZGF) |
|
ignition |
5 kV |
ambient temperature |
-20°C up to +80°C |
protection |
IP 54 |
Models | |
without electrical components |
ZGF... |
with integrated ignition transformer |
ZTF... |
with integrated ignition transformer and flame monitor for intermittend operation |
ZAF... |
with integrated ignition transformer und and flame monitor für continuous operation |
ZDAF... |
Product overview: gas igniters
Hegwein Heat release max. |
|
4 kW | |
![]() |
Ignition of gas burners up to 500 kW |
![]() |
Application in heat treatment plants and where space is limited |
Common Data | |
tube Ø |
25 mm |
flame length |
max. 100 mm |
igniter tube length L |
120 – 4000 mm |
gas inlet |
1/4“ |
gas pressure |
15 – 20 mbarg |
air inlet |
3/8“ |
air pressure |
15 – 20 mbarg |
Transformer part (not ZGU) |
|
ignition |
5 kV |
ambient temperature |
-20°C up to +80°C |
protection |
IP 54 |
Models | |
without electrical components |
ZGU... |
with integrated ignition transformer |
ZTU... |
with integrated ignition transformer and flame monitor for intermittend operation |
ZAU... |
with integrated ignition transformer and flame monitor für continuous operation |
ZDAU... |
Product overview: gas igniters