DC-JA7 |
|
|
|
Easy to see! |
|
Kinds |
Addition type total counter |
|
|
Model No. |
DC-JA7-AW |
DC-JA7-DW |
|
Power source |
100 to 240VAC(50/60Hz) |
12 to 24VDC(Ripple 20% or less) |
|
Fluctuation range |
85 to 250VAC |
12 to 24VDC±10% |
|
Power consumption |
1.2VA(when 240VAC) |
0.7W(when 24VDC) |
|
Front size |
24×48mm |
|
|
Number of digit |
7 digits(8 digits with overflow display) |
|
|
Display |
7-segment LCD(LED backlight), height 9mm, width 2.95mm |
|
|
Memory function |
EEP-ROM(Re-writing 0.1 million times or more) |
|
|
Counting speed |
30Hz/1kHz changeover, |
|
|
Input signal |
Contact and open-collector(flow current when short-circuited : approx. 4mA) |
|
|
Ambient temperature/humidity |
-10 to +50 degrees C(-25 to +55 degrees Cwhen stored), 35 to 85%RH |
|
|
Insulation resistance |
100MΩ or more(500VDC megger) between conducting terminal and uncovered non-charged metal |
|
|
Withstand voltage |
2000VAC/min. between conducting terminal and uncovered non-charged metal |
|
|
Noise resistance |
Square-wave noise by noise simulator(Rising 1nsec, width 1µsec) |
|
|
Static electricity |
10kV but 8kV when malfunction |
|
|
Vibration resistance |
Double amplitude 4mm, 16.7Hz (Malfunction : Double amplitude 0.5mm, 10 to 55Hz), each 1 hour in X, Y and Z direction |
|
|
Impact resistance |
294m/s2( Malfunction : 98m/s2) each 3 time in X, Y and Z direction |
|
|
Starting time when Power-ON |
2sec or less |
|
|
Protective structure |
IP66(Only front panel : must be using rubber packing) |
|
|
Case material |
Polycarbonate |
|
|
Weight |
Approx. 70g |
|
|
Attachment |
Mounting hook, rubber packing |
|
Counter

Panel-cut dimension

|
DC-JA(AC power) |
DC-JA(DC power) |
![]() |
![]() |
[Caution]
* Use the solderless terminal for M3.
* Use 2-core shield wire or metal wire tube and make it as short as possible. Don't make parallel wiring with power cable or high voltage cable etc.
* Counting input can't be accepted for 2sec after putting power source in.
Input(count/reset)

[Caution]
* Each input circuit of DC-JA series is common use for contact and transistor. Flow current from the counter is approx. 4mA. Use the relay for little current in case of contact input.
More Info Price
|
DC-JM |
|
|
|
12 pcs of counters are built-in |
|
Kind |
Increment type preset counter |
|||
|
Model No. |
DC-JM4-AW |
DC-JM4-DW |
DC-JM6-AW |
DC-JM6-DW |
|
Power source |
100 to 240VAC |
24VDC |
100 to 240VAC |
24VDC |
|
Fluctuation range |
±10% when 24VDC, 85 to 250VAC |
|||
|
Power consumption |
4VA*1(when 240VAC) |
1W(when 24VDC) |
4VA*1(when 240VAC) |
1W(when 24VDC) |
|
Built-in counter numbers |
12 |
|||
|
Preset |
1 preset |
|||
|
Output numbers |
1 output(12 pcs of counter, OR output) |
|||
|
Divider function |
1/100 |
|||
|
Memory function |
EEP-ROM(Re-writing 0.1 million times or more) |
|||
|
Counting speed |
Changeover for 30Hz/5kHz |
|||
|
Display |
7-segment LCD(LED back-light) |
|||
|
Input signal |
Contact or open-collector |
|||
|
Output |
Transistor output(NPN open-collector) : 100mA or less, 40V or less |
|||
|
Control output |
Transistor output(NPN open-collector) : 100mA or less, 40V or less |
|||
|
Power source for sensor |
12VDC, 50mA*2 |
12VDC, 50mA*2 |
||
*1 It includes external power source.
*2 In case of using 120VAC or less as power source, possible to supply 100mA outside
Counter

60→48 frame(GZ00003)
Use this frame when using DC-J instead of our counter with 60×60 such as DC-NXB, DC-S series.

|
AC Power |
DC Power |
![]() |
![]() |
|
Note)Power source for sensor isn't provided. |
(Caution)
| 1. | Don't use empty terminal as relay terminal. |
| 2. | Each input for counting and reset is common use for contact and transistor. Make a wiring with 2-core shield wire and metal as short as possible. Also, don't make a wiring with power and high voltage line etc. |
| 3. | Use solderless terminal for M3. |
| 4. | DC-J doesn't operate for approx. 2.5 sec after putting power source in. |
|
Input(counting/counter No.choice) |
Transistor output |
|
|
|
|
|
|
|
|
|
DC-M |
LED display DIN size |
|
|
Easy operation, clear display & easy pre-set |
72×72mm type
|
Type |
Increment/decrement type total counter |
Increment/decrement type preset counter |
|
Model No. |
DC-MA6-D |
DC-MB6-D |
|
Display |
Red LED 7-segment LED(Height10mm, width5.7mm), Range: 999999 to -99999 (Zero-suppress) |
|
|
Number of digit |
6 digits |
|
|
Power source |
100 to 240VAC(50/60Hz) |
|
|
Fluctuation range |
-15% to +10% |
|
|
Power consumption |
Approx. 4.5VA(when 240VAC) |
|
|
Counting |
Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H” |
|
|
Preset |
1 |
|
|
Preset method |
Digital switch for each digit |
|
|
Counting speed |
30Hz: Min. signal width 16.7msec, make-ratio 1:1 |
|
|
Counting prohibited |
Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz) |
|
|
Counting/ reset/counting prohibited input |
Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened) |
|
|
Control output operation |
Self-holding operation: It operates when preset value and returns by reset |
|
|
Power source for sensor |
12VDC(+10%, -10%), 100mA(Ripple 5% or less) |
|
|
Ambient temperature, humidity |
-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH |
|
|
Memory time against power failure |
Memory time/once: approx. 10 years, memory numbers: 0.1 million times |
|
|
Case |
Case: ABS resin, dust-proof cover: polycarbonate |
|
|
Attachment |
Dust-proof cover, fitting metal |
|
72×144mm type
|
Type |
Increment/decrement type total counter |
Increment/decrement type preset counter |
Increment/decrement type 2-preset counter |
|
Model No. |
DC-MA6-E |
DC-MB6-E |
DC-MC6-E |
|
Display |
Red LED 7-segment LED(Height15mm, width8.8mm), Range: 999999 to -99999 (Zero-suppress) |
||
|
Number of digit |
6 digits |
||
|
Power source |
100 to 240VAC(50/60Hz) |
||
|
Fluctuation range |
-15% to +10% |
||
|
Power consumption |
約4.5VA(when 240VAC) |
||
|
Counting |
Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H” |
||
|
Preset |
1 |
2 |
|
|
Preset method |
Digital switch for each digit |
||
|
Counting speed |
30Hz: Min. signal width 16.7msec, make-ratio 1:1 |
||
|
Counting prohibited |
Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz) |
||
|
Counting/ reset/counting prohibited input |
Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened) |
||
|
Control output operation |
Self-holding operation: It operates when preset value and returns by reset |
||
|
Power source for sensor |
12VDC(+10%, -10%), 100mA(Ripple 5% or less) |
||
|
Ambient temperature, humidity |
-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH |
||
|
Memory time against power failure |
Memory time/once: approx. 10 years, memory numbers: 0.1 million times |
||
|
Case |
Case: ABS resin, dust-proof cover: polycarbonate |
||
|
Attachment |
Dust-proof cover, fitting metal |
||
* DC-MOW with BCD read-out output is also lined up. Ask us in details.。
|
72×72mm type |
|
![]() |
![]() |
|
|
|
72×144mm type |
|
![]() |
![]() |
|
|
Input/transister output
|
Contact/transister open-collector input |
Voltage input |
![]() |
![]() |
Connection
DC-M_Connection 72×72mm type
Contact/Open-collector input

Note) Count 1 terminal [8] is increment, Count 2 terminal [9] is decrement. In case of 90 phase-difference input, when Count 1 is shifted shifted by 90°, it is increment counting, and when Count 2 is shifted 90°, it is decrement counting.
Note) In case of Total counter, [4] [5] [6] terminal are not used.
Note) FG [3] terminals should be grounded.
DC-M_Connection 2×144mm type
Contact/Open-collector input

Note) Terminals [11] and [18] are connected inside
Note) Count 1 [12] is increment counting and Count 2 [13] is decrement counting. In case of 90°phase-difference input, when Count 1 is shifted by 90°, it is increment counting, and when Count 2 is shited by 90°, it is decrement counting.
Note) In case of total counter, [4] [5] [6] [7] [8] [9] [16] [17] terminals are not used.
Note) In case of preset counter (1 preset type), [4] [5] [6] [16] terminals are not used.
Note) FG ([3] terminal) should be grounded.
Caution note)
* Do not use unused terminal as relay terminal.
* Each input to counting, reset and count prohibition is common use for contact and open-collector. Wire to each input and output terminal 2-core shield wire or metal conduit tube as short as possible. Do not lay the wires close to or parallel to line cable, power cable or high voltage line.
* For connection, use M3 pressure connection terminals.
|
DC-JB/JC |
|
|
|
VARIOUS FUNCTIONS IN DIN SIZE(48×48)! |
|
Type |
1-preset counter |
2-preset counter |
||||||
|
Model No. |
DC-JB6 |
DC-JB6 |
DC-JB6 |
DC-JB6 |
DC-JC6 |
DC-JC6 |
DC-JC6 |
DC-JC6 |
|
Power source |
100 to 240VAC(50/60Hz) |
24VDC(ripple 20% or less) |
100 to 240VAC(50/60Hz) |
24VDC(ripple 20% or less) |
||||
|
Fluctuation range |
±10% when 24VDC, 85 to 250VAC |
|||||||
|
Power consumption |
4VA*1(240VAC) |
1W(24VDC) |
5VA*1(240VAC) |
1W(24VDC) |
||||
|
Number of digit |
6 digits, -99999 to 999999(Total counter : 12 digits) |
|||||||
|
Memory function |
EEP-ROM(Re-writing 0.1 million times or more) |
|||||||
|
Counting speed |
Changeover for 30Hz/5kHz |
|||||||
|
Reset |
External reset, manual reset, automatic reset |
|||||||
|
Pre-scale |
0.001 to 9.999 |
|||||||
|
Decimal point position |
Lower 4 digits |
|||||||
|
Single-shot time |
0.005 to 9.999s |
|||||||
|
Display |
7-segment LCD(LED back-light) |
|||||||
|
Input mode |
Changeover for Increment/decrement independence, Phase-difference, Increment, Decrement, Increment/decrement command |
|||||||
|
Output mode |
Changeover for One-shot return, Self-holding free, One-shot free, Agree free, Comparing free |
|||||||
|
Output function |
Changeover for standard or digit-up |
Standard/Batch/Prediction |
||||||
|
Input signal |
Contact or open-collector, Impedance when ON(short-circuit) : 1k ohm or more, Impedance when OFF(short-circuit) : 100k ohm or more, Flowing current when short-circuit : approx. 4mA |
|||||||
|
Control output |
Transistor output(NPN open-collector) : 100mA or less, 40V or less |
|||||||
|
Power for sensor |
12VDC, 50mA |
12VDC, 50mA |
||||||
*1 It includes external power source.
*2 Only AC power type with 2-preset provides
Counter

60→48 frame(GZ00003)
Use this frame when using DC-J instead of our counter with 60×60 such as DC-NXB, DC-S series.

|
AC Power |
DC Power |
||
![]() |
![]() |
||
|
Note) Power source for sensor isn't provided. |
|
|
|
|
1. |
Don't use empty terminal as relay terminal. |
|
2. |
Each input for counting and reset is common use for contact and transistor. Make a wiring with 2-core shield wire and metal as short as possible. Also, don't make a wiring with power and high voltage line etc. |
|
3. |
Use solderlss terminal for M3. |
|
4. |
Function of output 1 is different between DC-JB and DC-JC. DC-JB : carry output, DC-JC : standard, batch and prediction output(depending on counter mode). Output 2 is standard output for both DC-JB and DC-JC. |
|
Input(Counting1/Counting2/Reset) |
Transistor output |
|
|
|
|
|
|
|
|
|