| Innovative measuring device with laser technology to monitor small to medium dust emission according to the new European regulations
|
|
|
Features |
|
|
Integrated display: Measuring value, threshold value, parameter in probe |
|
|
In-situ measuring procedure with continuous measurement |
|
|
High sensitivity |
|
|
Easy installation on one side of the duct |
|
| Can also be deployed in thick-walled stone/insulated channels | |
| Long lifetime, as there are no moving parts inside the duct | |
| Hermetically sealed electronic housing against exhaust gas | |
| Parameterisation and operation with keyboard plus easily readable display directly on device or via bus interface | |
| Automatic function test with soiling correction | |
| Two analog outputs with adjustable measuring ranges | |
| Automatic switching of measuring ranges according to 17. BImSchV. | |
|
Applications |
|
| Power stations | |
| Cement plants, the metallurgy and wood industries, chemical industry etc. | |
| Waste incineration plants | |
|
Monitoring of dust filter plants. |
|
|
|
|
|
measurements |
dust concentration |
|
measuring ranges |
0–10 mg/m3 ... 0–200 mg/m3 1) |
|
measuring principle |
forward scattering |
|
flue gas temperature |
above dew point up to 220 °C |
|
flue gas pressure |
-50 up to+10 hPa |
|
duct diameter |
1–8 m |
|
ambient temperature |
-20 up to +50°C |
|
protection |
IP65 |
|
measuring outputs |
2 x 0 / 4–20 mA / 500 Ohm, |
|
digital outputs |
4 relay outputs, programmable, |
|
digital inputs |
2 potential free inputs, programmable |
|
accuracy |
<2% of measuring range |
|
detection limit |
<2% of measuring range |
|
reference point drift |
<2% of measuring range/month |
|
zero point drift |
<2% of measuring range/month |
|
supply voltage |
85–264 VAC, 47–63 Hz, 50 VA |
|
dimensions (H x W x D) |
measuring lance: |
|
weight |
measuring lance: 7 kg |
|
remarks |
1) after gravimetric calibration |
|
purge air supply |
integrated into supply unit |